Multi-purpose STYROFOAMâ„¢ Brand SM Insulation Extruded Polystyrene is especially suited for foundations, slabs, crawl spaces, interior basements, geotechnical and other in-ground insulation applications. The Type 4 extruded polystyrene foam insulation helps protect foundation damp-proofing and waterproofing, especially during backfilling and provides a secondary barrier against groundwater leakage.
STYROFOAM™ Brand SM Insulation also provides energy-efficient performance in many other types of commercial and residential applications, including attics and ceilings.
Building Code Compliance
CAN/ULC S701 Type 4, CCMC 06525-L
Related Information
Add Value With STYROFOAM™ Insulation Solutions (219KB PDF)
Ajouter de la valeur grâce aux Solutions Isolantes STYROFOAM™ (258KB PDF)
Isolation Du Périmétre Et Sous La Dalle Spécification-type abrégée (Perimeter and Below Slab Insulation Guide Specification – French) (20KB PDF)
Isolation Du Périmétre Et Sous La Dalle Spécification-type abrégée (Perimeter and Below Slab Insulation Guide Specification – French) (44KB DOC)
STYROFOAM™ SM Insulation Product Information (87KB PDF)
Canada Residential
Multi-purpose STYROFOAMâ„¢ Brand SM Insulation is especially suited for foundations, slabs, crawl spaces, interior basements, geotechnical and other in-ground insulation applications. It also provides energy-efficient performance in many other types of commercial and residential applications, including attics and ceilings.
Installation Instructions for STYROFOAM CLADMATE/CLADMATE XL, STYROFOAM WALLMATE and STYROFOAM SM – Finished and Unfinished Attics
Installing SM/CLADMATE/WALLMATE in Cathedral/Vaulted Ceiling (Gypsum Board Exposed Inside Ceiling w/STYROFOAM Between Gypsum and Wood Framing)
Installing SM/CLADMATE/WALLMATE in Cathedral/Vaulted Ceiling (Exposed Beams Inside Ceiling w/STYROFOAM on top of Exposed Tongue & Groove Decking)
Installing STYROFOAM CLADMATE/CLADMATE XL or STYROFOAM SM – Interior of Basement Wall
Installing STYROFOAM CLADMATE/CLADMATE XL or STYROFOAM SM – Interior of Basement Wall with Stud Wall Framing and Batt Insulation
| Nominal Board Thickness(1), in (mm) | R-Value(2)Â (RSI) | Board Size, ft (mm) | Edge Treatment | Min Compressive Strength(3), psi (kPa) |
| 1.0 (25) | 5.0 (0.88) | 2 x 8 (600 x 2400) | Butt Edge/Shiplap | 30 (210) |
| 1.5 (38) | 7.5 (1.32) | 2 x 8 (600 x 2400) | Butt Edge/Shiplap | 30 (210) |
| 2.0 (50) | 10.0 (1.76) | 2 x 8 (600 x 2400) | Butt Edge/Shiplap | 30 (210) |
| 2.4 (61) | 12.0 (2.11) | 2 x 8 (600 x 2400) | Shiplap | 30 (210) |
| 2.5 (64) | 12.5 (2.2) | 2 x 8 (600 x 2400) | Shiplap | 30 (210) |
| 3.0 (75) | 15 (2.64) | 2 x 8 (600 x 2400) | Butt Edge/Shiplap | 30 (210) |
| 4.0 (102) | 20 (3.52) | 2 x 8 (600 x 2400) | Butt Edge/Shiplap | 30 (210) |
|
(1) Not all product sizes are available in all regions. (2) R means resistance to heat flow. The higher the R-value or RSI (R-Value Système Internationale), the greater the insulating power. R-values are expressed in ft2• h•°F/Btu. RSI values are expressed in m2 °C/W. R-value determined by ASTM C518. (3) Vertical compressive strength is measured at 10% deformation or at yield, whichever occurs first. |
||||
Â
07 20 00 Board Insulation
We're here to help. If you're not finding the information you need, please let us know.
Canada Commercial
Multi-purpose STYROFOAMâ„¢ Brand SM Insulation is especially suited for foundations, slabs, geotechnical and other in-ground insulation applications. The Type 4 foam helps protect foundation damp-proofing and waterproofing, especially during backfilling and provides a secondary barrier against groundwater leakage.
| Nominal Board Thickness(1), in (mm) | R-Value(2) (RSI) | Board Size, ft (mm) | Edge Treatment | Min Compressive Strength(3), psi (kPa) |
| 1.0 (25) | 5.0 (0.88) | 2 x 8 (600 x 2400) | Butt Edge/Shiplap | 30 (210) |
| 1.5 (38) | 7.5 (1.32) | 2 x 8 (600 x 2400) | Butt Edge/Shiplap | 30 (210) |
| 2.0 (50) | 10.0 (1.76) | 2 x 8 (600 x 2400) | Butt Edge/Shiplap | 30 (210) |
| 2.4 (61) | 12.0 (2.11) | 2 x 8 (600 x 2400) | Shiplap | 30 (210) |
| 2.5 (64) | 12.5 (2.2) | 2 x 8 (600 x 2400) | Shiplap | 30 (210) |
| 3.0 (75) | 15 (2.65) | 2 x 8 (600 x 2400) | Butt Edge/Shiplap | 30 (210) |
| 4.0 (102) | 20 (3.52) | 2 x 8 (600 x 2400) | Butt Edge/Shiplap | 30 (210) |
| 50 mm | 10.0 (1.76) | 600 mm x 2400 mm | Butt Edge/Shiplap | 30 (210) |
| 75 mm | 15.0 (2.65) | 600 mm x 2400 mm | Butt Edge/Shiplap | 30 (210) |
|
(1) Not all product sizes are available in all regions. (2) R means resistance to heat flow. The higher the R-value or RSI (R-Value Système Internationale), the greater the insulating power. R-values are expressed in ft2• h•°F/Btu. RSI values are expressed in m2°C/W. R-value determined by ASTM C518. (3) Vertical compressive strength is measured at 10% deformation (5% for STYROFOAM™ Brand HIGHLOAD 40, 60 and 100 Insulation products) or at yield, whichever occurs first. Since STYROFOAM™ Brand Extruded Polystyrene products are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep. For static loads, 3:1 is suggested. For dynamic loads, 5:1 is suggested. |
||||
Â
07 20 00 Board Insulation
We're here to help. If you're not finding the information you need, please let us know.