STYROFOAM™ Brand RECOVERMATE™ CR Insulation is a fanfolded extruded polystyrene foam board with poly-coated kraft facers as a protective layer between the existing roof and new recovery membrane. This insulation is compatible with a new ballasted or light-colored mechanically attached sheet membrane. Facers provide puncture and chemical resistance.
Building Code Compliance
Meets IBC/IRC requirements for foam plastic insulation. See ESR-2142, BOCA-ES RR 21-02, ICBO-ES ER-2257. UL Classified, see Classification Certificate D369.
Related Information
STYROFOAM™ RECOVERMATE™ CR Insulation Product Information (132KB PDF)
U.S. Commercial
STYROFOAM™ Brand RECOVERMATE™ CR Insulation is fanfolded with poly-coated kraft facers as a protective layer between the existing roof and new recovery membrane.
| Nominal Board Thickness, in | R-Value(1) | Board Size, ft | Edge Treatment | Min Compressive Strength(2), psi |
| 0.375 Fanfold boards folded every 2' |
1.5 | 4 x 50 | Square Edge | 15 |
|
(1) R means resistance to heat flow. The higher the R-value, the greater the insulating power. R-values are expressed in ft2• h•°F/Btu. R-value determined by ASTM C518. (2) Vertical compressive strength is measured at 10% deformation (5% for STYROFOAM™ Brand PLAZAMATE™ Insulation and for STYROFOAM™ Brand HIGHLOAD 40, 60 and 100 Insulation products) or at yield, whichever occurs first. Since STYROFOAM™ Brand Extruded Polystyrene and Dow polyisocyanurate insulation products are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep. For static loads, 3:1 is suggested. For dynamic loads, 5:1 is suggested. |
||||
07 22 16 Roof Board Insulation (Conventional Membrane Systems)
07 50 00 Conventional Membrane Roofing Insulation
For additional information on STYROFOAM™ Brand RECOVERMATE™ CR Insulation visit http://www.adamsplasticsinc.com/
We're here to help. If you're not finding the information you need, please let us know.
Canada Commercial
STYROFOAM™ Brand RECOVERMATE™ CR Insulation is fanfolded with poly-coated kraft facers as a protective layer between the existing roof and new recovery membrane.
| Nominal Board Thickness, in (mm) | R-Value(1) (RSI) | Board Size, ft (m) | Edge Treatment | Min Compressive Strength(2), psi (kPa) |
| 0.375 Fanfold boards folded every 2' (600 mm) |
1.5 (0.26) | 4 x 50 (1.2 X 15.2) | Butt Edge | 15 (105) |
|
(1) R means resistance to heat flow. The higher the R-value or RSI (R-Value Système Internationale), the greater the insulating power. R-values are expressed in ft2 • h•°F/Btu. RSI values are expressed in m2°C/W. R-value determined by ASTM C518. (2) Vertical compressive strength is measured at 10% deformation (5% for STYROFOAM™ Brand HIGHLOAD 40, 60 and 100 Insulation products) or at yield, whichever occurs first. Since STYROFOAM™ Brand Extruded Polystyrene products are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep. For static loads, 3:1 is suggested. For dynamic loads, 5:1 is suggested. |
||||
07 22 16 Roof Board Insulation (Conventional Membrane Systems)
07 50 00 Conventional Membrane Roofing Insulation
For additional information on STYROFOAM™ Brand RECOVERMATE™ CR Insulation visit http://www.adamsplasticsinc.com/