STYROFOAM™ Brand DECKMATE™ Plus Insulation is a Type IV extruded polystyrene foam product designed for use on conventional roofs beneath mechanically fastened, fully adhered or ballasted sheet membranes. It can be used on built-up, modified bituminous and metal roofs, and installed directly on a steel deck without the use of a thermal barrier such as gypsum board.
Building Code Compliance
Complies with ASTM C578 Type IV. Meets CAN/ULC S701 Type 2. Meets IBC/IRC requirements for foam plastic insulation. See ESR-2142, BOCA-ES RR 21-02, CCMC – Evaluation Listing #12085-L. UL Classified, see Classification Certificate D369.
3D Model Using STYROFOAM™ DECKMATE™ Plus Roof Insulation – Steep Slope Roof – Metal Framing (157KB)
This 3D Model uses Google SketchUp. Please visit the Google Web site to download SketchUp.
STYROFOAMâ„¢ Brand DECKMATEâ„¢ Plus CAD Details
Related Information
STYROFOAM™ DECKMATE™ Plus Extruded Polystyrene Insulation Product Information (51KB PDF)
STYROFOAM™ DECKMATE™ Plus Insulation Products: Direct-to-Deck Application Information (114KB PDF)
20-Year Limited Thermal Warranty (54KB PDF)
20-Year Limited Thermal Warranty – MBCI (168KB PDF)Â
STYROFOAM™ DECKMATE™ Plus Reuse Warranty (110KB PDF)
The Direct Approach: STYROFOAM™ DECKMATE™ Plus for Direct Application to Metal Decks (428KB PDF)
Conventional Roof Sell Sheet – Performance, Strength and Comfort (1.03MB PDF)
Conventional Roofing Membrane Insulation Guide Specification (French) (20KB PDF)
Conventional Roofing Membrane Insulation Guide Specification (French) (46KB DOC)
U.S. Commercial
STYROFOAMâ„¢ Brand DECKMATEâ„¢ Plus Insulation Extruded Polystyrene is designed for use on conventional roofs beneath mechanically fastened, fully adhered or ballasted sheet membranes. It can be used on built-up, modified bituminous and metal roofs, and installed directly on a steel deck without the use of a thermal barrier such as gypsum board.
| Nominal Board Thickness(1), in | R-Value(2) | Board Size, ft | Edge Treatment | Min Compressive Strength(3), psi |
| 2.0 | 10.0 | 2 x 8Â / 4 x 8 | Square Edge | 25 |
| 2.5 | 12.5 | 4 x 8 | Square Edge | 25 |
| 3.0 | 15.0 | 2 x 8Â / 4 x 8 | Square Edge | 25 |
| 4.0 | 20.0 | 2 x 8Â / 4 x 8 | Square Edge | 25 |
|
(1) Not all product sizes are available in all regions. (2) R means resistance to heat flow. The higher the R-value, the greater the insulating power. R-values are expressed in ft2 • h•°F/Btu. RSI values are expressed in m2°C/W. R-value determined by ASTM C518. (3) Vertical compressive strength is measured at 10% deformation (5% for STYROFOAM™ Brand PLAZAMATE™ Insulation and for STYROFOAM™ Brand HIGHLOAD 40, 60 and 100 Insulation products) or at yield, whichever occurs first. Since STYROFOAM™ Brand Extruded Polystyrene and Dow polyisocyanurate insulation products are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep. For static loads, 3:1 is suggested. For dynamic loads, 5:1 is suggested. |
||||
Â
07 22 16 Roof Board Insulation (Conventional Membrane Systems)
07 50 00 Conventional Membrane Roofing Insulation
We're here to help. If you're not finding the information you need, please let us know.
Canada Commercial
STYROFOAM™ Brand DECKMATE™ Plus Insulation is designed for use on conventional roofs beneath mechanically fastened, fully adhered or ballasted sheet membranes. It can be used on built-up, modified bituminous and metal roofs, and installed directly on a steel deck without the use of a thermal barrier such as gypsum board.
| Nominal Board Thickness, in (mm) | R-Value(1) (RSI) | Board Size, ft (mm) | Edge Treatment | Min Compressive Strength(2), psi (kPa) |
| 4.0 (100) | 20.0 (3.52) | 2 x 8 (600 x 2400) | Shiplap | 20 (140) |
|
(1) R means resistance to heat flow. The higher the R-value, the greater the insulating power. R-values are expressed in ft2 • h•°F/Btu. RSI values are expressed in m2°C/W. R-value determined by ASTM C518. (2) Vertical compressive strength is measured at 10% deformation (5% for STYROFOAM™ Brand HIGHLOAD 40, 60 and 100 Insulation products) or at yield, whichever occurs first. Since STYROFOAM™ Brand Extruded Polystyrene products are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep. For static loads, 3:1 is suggested. For dynamic loads, 5:1 is suggested. |
||||
Â
07 22 16 Roof Board Insulation (Conventional Membrane Systems)
07 50 00 Conventional Membrane Roofing Insulation
We're here to help. If you're not finding the information you need, please let us know.