Македонија - STYROFOAM SM-TG-A


Properties 1) Standard Unit STYROFOAM SM-TG-A 2)
Density (minimum) EN 1602 kg/m3 32
Thermal conductivity
- 90 days value at 10°C
- declared value 3) - λ d

PrEN 12667
PrEN 12939

W/m.K
W/m.K
0.033 max
Vapour diffusion factor, µ EN 12086 80-200
Water absorption by immersion (28 days) EN 12087 Vol. % <0.5
Capillarity 0
Compressive strength
- at yield or 10% deflection
- design value at long-term loads 4)

EN 826
EN 1606

N/mm2
N/mm2

0.25
>0.08
Max. service temperature °C -50/+75
Linear thermal expansion coefficient mm/m.K 0.07
Surface Skin
Edge profile All around tongue and groove
Dimensions
- length x width
- thickness

EN 822
EN 823

mm
mm


2500 x 600
30, 50

1) Mean values, if otherwise not defined
2) CFC-, HCFC- and HFC-free product
3) Also design value at dry or periodically moist application environment, in inverted roofs and ground-water add 5%
4) Design value for constant live loads occurring max. 2% deflection in long term
5) Available upon request