Interlocking concrete paving blocks can be laid on a crushed sand/gravel bed above a separation sheet and FLOORMATE™ 700-A boards. Up to a weight of 3.5 tons of cars, a load distribution slab is not required above the insulation. At low intensity traffic or limited grade loads FLOORMATE 500-A boards may also be sufficient. For intensive traffic and heavyweight vehicles a load distribution reinforced concrete slab must be installed on a min. 3 cm 4/8 mm crushed gravel bed above a separation sheet and the FLOORMATE 500-A or FLOORMATE 700-A insulation.
|

|
- Sand diam 0/2 mm
- Concrete paving slabs 100 mm
- Gravel diam. 2/8 mm, 50 mm thickness
- Geotextile separation - diffusion layer (polypropylene) 110-140 gm2, 200 mm thickness
- FLOORMATE 500-A (FLOORMATE 700-A) depending on requested compressive strength
- Bituminous water proofing membrane
- Concrete layer
|
|
|

|
- Concrete layer
- Separation layer
- Gravel diam 4/8 mm, layer of 30-40 mm thickness
- Geotextile separation - diffusion layer (polypropylene) 110-140 gm2, 200 mm thickness
- FLOORMATE 500-A (FLOORMATE 700-A) depending on requested compressive strength
- Bituminous waterproofing membrane
- Concrete layer
|
|